Solar Calculator Canada

Solar Power Calculator for Lake Lenore, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lake Lenore
  • GPS Coordinates: 52.3958583, -104.9853322
  • Elevation: 552 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lake Lenore: 43o
  • Average yearly irradiance: 1475.89 kWh/m2
  • Average yearly power output: 126074 kWh

Average yearly irradiance delivered by the Sun in Lake Lenore is 1475.89/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 126074 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.66 51.61
February 2.55 71.42
March 3.44 106.72
April 5.15 154.46
May 6.01 186.27
June 5.69 170.83
July 6.3 195.2
August 5.85 181.26
September 4.87 146.16
October 3.54 109.63
November 1.89 56.62
December 1.47 45.72
Total yearly 1475.89

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 161 4990.86
February 243.17 6808.74
March 312.07 9674.12
April 445.7 13370.9
May 503.72 15615.5
June 464.24 13927.3
July 507.39 15729
August 473.91 14691.2
September 406.51 12195.2
October 308.38 9559.83
November 171.87 5156.22
December 140.49 4355.31
Total yearly 126074

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lake Lenore solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 97.69 3028.29
February 168.9 4729.23
March 257.13 7971.12
April 421.59 12647.8
May 522.31 16191.7
June 502.25 15067.5
July 536.24 16623.4
August 463.97 14382.9
September 352.65 10579.4
October 230.74 7152.98
November 111.96 3358.88
December 81.41 2523.81
Total yearly 114257

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.75 3464.32
February 185.92 5205.64
March 271.29 8410.05
April 431.67 12950.1
May 525.62 16294.3
June 500.6 15018
July 537.28 16655.7
August 471.86 14627.6
September 367.91 11037.2
October 248.92 7716.45
November 125.34 3760.23
December 94.44 2927.56
Total yearly 118067

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.63 3863.65
February 201.28 5635.8
March 283.55 8790.15
April 439.25 13177.5
May 525.89 16302.5
June 497.73 14931.8
July 535.86 16611.7
August 476.98 14786.5
September 380.77 11423
October 265.2 8221.11
November 137.56 4126.93
December 106.44 3299.54
Total yearly 121170

Lake Lenore Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.31 4225.48
February 214.97 6019.04
March 293.89 9110.68
April 444.3 13329.1
May 523.26 16221.1
June 491.44 14743.2
July 531.13 16465.1
August 479.42 14861.9
September 391.19 11735.8
October 279.53 8665.36
November 148.59 4457.77
December 117.37 3638.49
Total yearly 123473

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.42% temperature and irradiance loss. This totals to about -14.58%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: